skip navigation

CrimeSolutions.gov

Add your conference to our Justice Events calendar

PUBLICATIONS

NCJRS Abstract

The document referenced below is part of the NCJRS Library collection.
To conduct further searches of the collection, visit the NCJRS Abstracts Database.

How to Obtain Documents
 
NCJ Number: NCJ 224148   Add to Shopping cart   Find in a Library
Title: Test Results for Mobile Device Acquisition Tool: Micro Systemation .XRY 3.6
Corporate Author: National Institute of Standards and Technology (NIST)
United States of America
Date Published: 05/2008
Page Count: 145
Sponsoring Agency: National Institute of Justice
US Department of Justice
Office of Justice Programs
United States of America
Grant Number: 2003-IJ-R-029
Sale Source: National Institute of Justice/NCJRS
Box 6000
Rockville, MD 20849
United States of America
Document: PDF 
Type: Test/Measurement
Language: English
Country: United States of America
Annotation: As part of the Computer Forensics Tool Testing (CFTT) program--whose objective is to provide measurable assurance to practitioners, researchers, and other applicable users that the tools used in computer forensics investigation provide accurate results--this report presents the results of testing Micro Systemation. XRY, version 3.6, a mobile device data acquisition tool.
Abstract: With the exception of two test cases (CFT-IM-05 and CFT-IM-06), the tested tool acquired all supported data objects completely and accurately from the following selected test mobile devices and associated media: the Nokia 6101, T-Mobile SIM, Motorola TAZR V3, and AT&T SIM. Regarding one exception (CFT-IM-05), the MSISDN was not reported for the Nokia 6101 after a successful internal memory acquisition. For the second exception (CFT-IM-06), the maximum length notes created on the Nokia 6101 were truncated, preventing the entire message from being acquired. The tool reports a maximum of 184 characters within a note. The tool was tested against the GSM Mobile Device and Associated Media Tool Specification and Test Plan Version 1.1. The report’s section on test case selection contains a table that lists the features available in Micro Systemation .XRY and the linked test cases. A second table lists the features not available in the device and the linked test cases. The report’s section on results by test assertion contains a table that summarizes the test results by assertion. For each assertion, the number of test cases that use the given assertion is indicated. For each assertion that involves an anomaly, the table provides the report’s section number where the anomaly is discussed. Another section of the report describes the testing environment, including the test computers. The report’s concluding section provides the test results report key and the details of each test result. Extensive data tables
Main Term(s): Computer aided investigations
Index Term(s): Data collection devices ; Data collection ; Equipment evaluation ; Investigative techniques ; NIJ grant-related documents